Provided with 2mV/V output signal and 9m long integral cable it is available in 4 standard capacities of 90t, 180t, 225t and 450t with an operating temperature range of 35 ~ 65c and a compensated range of – 10 ~ 50c makes the HCC the first choice for serious measurement professional.
SPECIFICATIONS | |||
Signal output at capacity Linearity Error Non-Repeatability Combined Error Hysteresis Creep/(30 mins) Zero Balance Temperature Effect On Span/10ºC Temperature Effect on Zero/10ºC Operating Temperature Range Compensated Temperature Range Storage Temperature Range Excitation +ve Signal +ve |
2±0.01 mV/V < 0.03% FSO < 0.010% FSO < 0.030% FSO < 0.030% FSO < 0.020% FSO < 1% Capacity < 0.02% FSO < 0.02% FSO -35 ~ 65 C -10 ~ 50 C -50 ~ 85 C RED GREEN |
Service Load Safe Load Safe Side Load Ultimate Load Input Resistance Output Resistance Insulation Resistance Excitation Voltage (Rec) Excitation Voltage (Max) Cable Material Sealing Excitation -ve Signal -ve |
100% Capacity 120% Capacity 10% of axial load 300% Capacity 450Ω ± 5Ω 480Ω ± 3Ω > 5000 MΩ (@50 VDC) 9 ~ 12 V AC/DC 15 V AC/DC 9m long, 6.0 mm dia. Alloy/Stainless Steel IP68 BLACK WHITE |
CAPACITIES
Model HCC-90t HCC-180t HCC-225t HCC-450t |
Capacity 90t 180t 225t 450t |
DIMENSIONS
Dimensions (mm) | ||||||||||||||
Capacity | Order | A | B | C | D | E | F | H | R | T | Weight(kg) | |||
90t | HCC0090T000XXX | 150.6 | 134.4 | 80.0 | 92.0 | 26.0 | 108.0 | 184.5 | 400 | M20x1.5.25 Deep | 14 | |||
180t | HCC0180T000XXX | 150.6 | 134.4 | 80.0 | 92.0 | 26.0 | 108.0 | 184.5 | 400 | M20x1.5 25 Deep | 14 | |||
225t | HCC0225T000XXX | 165.0 | 148.0 | 93.7 | 92.0 | 26.0 | 108.0 | 229.0 | 400 | M20x1.5. 25 Deep | 23 | |||
450t | HCC0450T000XXX | 177.0 | 165.1 | 139.7 | 117.0 | 22.0 | 115.0 | 304.8 | 1143 | M20x1.5. 32 Deep | 62 |